FSF-02
Capacitive
Vane Style
Liquid
Analog Type
SemiConductor Integrated
Metal
0.1G
IP67
CE
Customized
Flow Switch
yuanben
200PCS
123
Shanghai
9033000000
Product Description
FST-02 series flow sensor is available with a brass body and a choice of 304 stainless steel fittings.
FST-02 Flow Sensor use a turbine type flow sensor, is designed to measure the flow of water, other light transmitting, non-corrosive liquids of similar viscosity. Specifically for small diameter applications.
The turbine wheel flowmeters are an economical yet very reliable solution for measuring liquid flows
Characteristic
Parts name: Material and parameter
Farts:
Housing Brass C37700
Piston PVC or PBT
Spring Stainless steel
Retaining rings Stainless steel SUS 304
Operating pressure 300 PSI max
Temperature range -40~125deg. C
Carry current 1.5A
Switch current: 1.0Amax
Switch voltage: 300Vac, 250Vdc
Power rating: 70VA
Lead wire AWG 22, to 18, 300mm length, UL1430, free lead wire
Flow range: 0.75L~8.0L/min
Set point Accurancy: 10% max
Set point Differentive: 15%
Repeatability: 2% max
Mounting: Mounting orientation (Horizontal or vertical) as signal of flow direction Mounting orientation
Mounting thread: FNPT. 3/4",
Adequate filtration and sealing Procedures should be used when mounting in flow line
FST-02 Flow Sensor use a turbine type flow sensor, is designed to measure the flow of water, other light transmitting, non-corrosive liquids of similar viscosity. Specifically for small diameter applications.
The turbine wheel flowmeters are an economical yet very reliable solution for measuring liquid flows
Characteristic
Parts name: Material and parameter
Farts:
Housing Brass C37700
Piston PVC or PBT
Spring Stainless steel
Retaining rings Stainless steel SUS 304
Operating pressure 300 PSI max
Temperature range -40~125deg. C
Carry current 1.5A
Switch current: 1.0Amax
Switch voltage: 300Vac, 250Vdc
Power rating: 70VA
Lead wire AWG 22, to 18, 300mm length, UL1430, free lead wire
Flow range: 0.75L~8.0L/min
Set point Accurancy: 10% max
Set point Differentive: 15%
Repeatability: 2% max
Mounting: Mounting orientation (Horizontal or vertical) as signal of flow direction Mounting orientation
Mounting thread: FNPT. 3/4",
Adequate filtration and sealing Procedures should be used when mounting in flow line
Item | Technical Parameter |
Compatible | Clean fluid |
Accuracy | ±3% of reading |
Repeatability | ±0.5% of reading |
Nominal Flow Rates | From 0.1 to 1.0 or 0.8 to 10 gpm |
Temperature and Pressure | 16 bar @ 20ºC |
Rotor | PP or client required |
Body | PP or client required |
Bearings and Shaft | Ceramic or SUS304 1/2" 1/4" 3/8" flexible tubing |
Input Power | 5 to 24 VDC @ 1.0mA max |
Output Signal | Open collector NPN transistor sinking a maximum of 30mA |