Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 1Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 2Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 3Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 4Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 5Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130) image 6

Thermistors Range -40 to 300 Degree PTC Type Encapsulated in Resin (KTY84/130)

Nanjing Yumany Imp & Exp Co., Ltd.

Price $5.50 / Piece
Mini Order
-+Subtotal: $55
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

KTY84/130
Wall-Mounted Type
Thermocouple
Contact
Analog Type
Integration
Customized
MANYEE
Inner Box+Carton
China/Netherlands
Product Description
 
 
DESCRIPTION

The temperature sensors in the KTY84-1 series have a positive temperature coefficient of resistance and are suitable for use in measurement and control systems over a temperature range of -40 to +300 °C. The sensors are encapsulated in the SOD68 (DO-34) leaded package.

Tolerances of 0.5% or other special selections are available on request.

MARKING


 
TYPE NUMBERMARKING BAND COLOUR
  
KTY84-130yellow
  
KTY84-150grey
  
KTY84-151black
  
KTY84-152blue
  

QUICK REFERENCE DATA





 
ka

MLA427


The first (green) band indicates the negative connection. The second (coloured) band provides type identity.

The sensor must be operated with the lower potential at the marked connection.

Fig.1 Simplified outline (SOD68; DO-34).
 
 
SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT
      
R100sensor resistanceTamb = 100 °C; Icont = 2 mA   
 KTY84-130 9701030W
 KTY84-150 9501050W
 KTY84-151 9501000W
 KTY84-152 10001050W
      
Tambambient operating temperature -40+300°C

LIMITING VALUES

In accordance with the Absolute Maximum Rating System (IEC 134).


 
SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT
      
Icontcontinuous sensor currentin free air; Tamb = 25 °C; note 1-10mA
  in free air; Tamb = 300 °C-2mA
Tambambient operating temperature -40+300°C
Tstgstorage temperature -55+300°C

Note

1.  For temperatures greater than 200 °C, a sensor current of Icont = 2 mA must be used.
 
 
Philips Semiconductors  Product specification
       
Silicon temperature sensors  KTY84-1 series
       
CHARACTERISTICS     
Tamb = 100 °C, in liquid, unless otherwise specified.     
       
SYMBOLPARAMETERCONDITIONSMIN.TYP.MAX.UNIT
       
R100sensor resistanceIcont = 2 mA    
 KTY84-130 970-1030W
 KTY84-150 950-1050W
 KTY84-151 950-1000W
 KTY84-152 1000-1050W
       
TCtemperature coefficient -0.61-%/K
       
R250/R100resistance ratioTamb = 250 °C and 100 °C2.1112.1662.221 
R25/R100resistance ratioTamb = 25 °C and 100 °C0.5950.6030.611 
tthermal time constant; note 1in still air-20-s
       
  in still liquid; note 2-1-s
       
  in flowing liquid; note 2-0.5-s
       
 rated temperature range -40-+300°C
       

Notes
 
  1. The thermal time constant is the time taken for the sensor to reach 63.2% of the total temperature difference. For example, if a sensor with a temperature of 25 °C is moved to an environment with an ambient temperature of 100 °C, the time for the sensor to reach a temperature of 72.4 °C is the thermal time constant.