B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 1B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 2B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 3B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 4B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 5B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger image 6

B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger

Suzhou AEGEN New Engergy Technology Co., Ltd.

Price $55.00 / Pieces
Mini Order
-+Subtotal: $550
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

AG-VDF-2B-40A
Electro-Magnetic Type
AC 230(240)/400(415)
4000 Cycle
IP20
19mm
Screw Terminal
10000 Pole/Poles Per Month
AEGEN
Carton
36*78*81mm
China
8538900000
Product Description
Product Description

B Earth Leakage Current Breaker Type RCCB RCD for AC EV Charger
Residual current circuit breakers (RCCBs) 

This device is essentially a  attached to it. So basically it will only break the circuit when there is a leakage current flowing to earth. The tripping time is such as to minimise the risk to human life.

RCCBs usually have a fault making and . This means that they can handle a fault of 1 kA on their own if it is a fault to earth.

Type B residual current device disconnects the power if the earth leakage current is detected as dangerous. If the earth leakage current is equal to or less than 10mA, then the Type B residual current devices would not trip because this current amount is not dangerous. The electric car will continue to get charging without any interruption. The Type B residual current devices will immediately trip the circuit and disconnect the power supply for higher currents. Like this, Type B residual current devices will protect the circuits from danger.
                                                                        Technical Data
Model:AG-VDF-2B-63A
Pole No.:1P+N, 3P+N
Rated current(A):16A,25A, 32A, 40A, 63A,80A,100A 
Rated working voltage(I n):30, 100, 300, 500mA
Rated voltage(V):AC 230(240)/400(415)
Rated frequency(Hz):50/60
Rated making and breaking capacity:500(In=25A,32,40A), 630(In=63A)
Rated conditional short-circuit current Inc:10000A
Rated conditional residual short-circuit Current I c:10000A
Rated residual non operating current I no:0.5I n
Residual operating current range:0.5I n~I n
Operating time:≤0.3s
Type:A and AC type
Rated short-circuit breaking capacity:10000A
Mechanical life:2000 times
Degree of protection:IP20
Products name:Type B RCD | Type B RCCB | Detection residential RCCB 