BM200-DI/I
Analog Output
0.2G
IP20
Customized
DC0~20mA / 4~20mA
DC0~20mA / 4~20mA
1 in 1 out, 1 in 2 out, 2 in 2 out
DC20~35V
35mm DIN Rail Installation
Acrel
Carton
China
Product Description
Product Description

Model: BM200-DI/I
 

Input Signal: DC0~20mA / 4~20mA
 

Output Signal: DC0~20mA / 4~20mA
 

 Channel Type: 1 in 1 out, 1 in 2 out, 2 in 2 out
 

Power Supply: DC20~35V
 

35mm Din Rail Installation

BM200 isolated safety barrier can transmit signals between the safe area and the dangerous area, and limit the energy transfer from the safe area to the dangerous area caused by the fault. The voltage, current, temperature, resistance signals generated by the equipment (transmitter) on the dangerous side are isolated and converted into corresponding linear voltage and current signals outputting to the safe area. The product requires independent power supply, and the input/output/power supply is isolated. It can be used in current source, two-wire, three-wire transmitter equipment.
 

Type

BM200-DI/I-B11,BM200-DI/I-C12,BM200-DI/I-C22

Channel type

1 in 1 out, 1 in 2 out, 2 in 2 out

Input type

Current

Output signal

0~20mA/4~20mA (Distribution voltage: 14.0V/20mA)

Output Signal

0~20mA /4~20mA (safety side output); Load resistance: ≤550Ω

Transmission accuracy

0.2%

Temperature drift

50ppm

Response time

5ms to reach 90% of final value

Supply voltage

20~35V DC

Consumption

24V power supply, 20mA output: ≤70mA (one in, one out)

≤110mA (one in, two out)

≤160mA (two in and two out)

Working temperature

-20ºC~+60ºC

Storage temperature

-40ºC~+80ºC

Relative humidity

≤95%RH, no condensation, no corrosive gas place

Altitude

≤2500m

Protection level

IP20

Weight

About 110g (12.5mm shell)

About 150g (22.5mm shell)

Installation

Din-rail mounted

Dielectric strength

Intrinsically safe end and non-intrinsically safe end ≥ 2500V AC; power supply and non-intrinsically safe end ≥ 500V AC

Features

1. It can directly isolate the loop signal in the dangerous area from the signal in the safe area;
2. It can allow the instrument to be grounded on site, especially there are many protective function circuits, and it allows live maintenance on site;
3. Compared with other devices, analog signal voltage isolator is still very good in signal processing.
Dimension

Wiring

BM200-DI/I-B11
 

BM200-DI/I-C12

BM200-DI/I-C22
Structure

Application

Company Profile
 
Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.

 

Send Message

Content*

Your Name

Tel*

Email*

Shop Cart