The Full Name Of SF Is Steel Reinforced Glass Fiber Double-Layer Oil Tank. It Is A Double-Layer Structure Oil Tank Formed By Adding A Layer Of Glass Fiber Reinforced Plastic (Ie FRP) Anti-Seepage Jacket To The Outside Of The Single-Layer Steel Oil Tank. There Is A Through Gap Space Between The Steel Inner Tank And The FRP Outer Tank.
S/F Dual-Layer Oil Storage Tank Is More Safety, Environmental Protection And Economically, S Means Steel For Inner Tank Contacts With Oil Fuel, Like Petroleum, Diesel Etc, F Means FRP For Outer Shell Which Contacts With Soil, It Is Corrosion Resist, Isolation Etc, S/F Dual-Layer Oil Storage Tank Manufactured With Professional Equipments, And There Is Interlay Clearance Between Internal Steel Layer And External FRP Layer, High-Precision Inspection Device Is Connected With The Interlayer Clearance, Monitoring The Leakage All The Time.
The Reason For Fast Promotion And Application In The Market Of The Double Lagers Oil Tank Is From Its Sole Advantages Such As Safety, Environment Protection, And Low-Cost Comparison With Sing Layer Steel Oil Tank. it Is Composed Of Steel Inner Tank And Fiberglass Reinforced Outer Tank Made By Special Equipment With a Patent. The Underground Tank Possess A Uniform Inter-Layer Space Which is Connected To a Leakage Detector and Can Monitor The Leakage At Any Time.
Working Principle
Anti-Seepage Principle Of Double-Layer SF Oil Storage Tank: Double-Layer SF Oil Storage Tank Is Composed Of An Inner Tank And An Outer Tank That Completely Seals The Inner Tank. There Is A Gap in Space Between The Inner Tank And The Outer Tank For Installing A Leak Detection System. The Material Of The Outer Tank Is Usually Made Of Anti-Corrosion Metal, Epoxy Resin, Glass Fiber Reinforced Plastic Or Metal Coated With Synthetic Film.
The Interstitial Space Needs To Be Sufficient To Fully Contain The Storage Fluid Leaking From The Inner Tank. The Leak Detection System Satisfies The Whole Process Of Monitoring Or Sends Out An Alarm When A Leak Occurs.
The Anti-Seepage Principle Of Double-Layer SF Oil Storage Tank Is Roughly Like This. The Leakage Monitoring Method Of Double-Layer SF Oil Storage Tank Is Mainly Divided Into Pressure Vacuum Monitoring Method And Liquid Medium Monitoring Method. Both Monitoring Systems Can Monitor The Change Of Air Pressure Or Liquid Level. , To Determine Whether There Is Seepage Or Leakage In The Storage Tank
Structural Properties
2. Outer Layer-The Thickness Of Tempered Glass Fiber Reaches More Than 4.0Mm, Which Has Good Compression And Shock Resistance. Has Strong Corrosion Resistance And Electrical Corrosion Resistance:
3. The Unique Process Technology Is Adopted Between The Inner And Outer Layers To Make It Reach A Gap Of About 0.1Mm To 3.5Mm, Eliminating The Existence Of Hidden Dangers From The Root. The Leak Detector Monitors 24 Hours A Day To Eliminate Potential Safety Hazards Caused By Leakage
Product Name | S/F Double Wall Fuel Tanks |
Keywords | Fiberglass/Steel Double Wall Fuel Tanks |
Capacities | 5000-100000LOr Customized |
Weight | 1-100t |
Type | Horizontal |
Color | Customers'Demands |
Usage | Store |
Showroom Location | Egypt, Turkey, France, Viet Nam, Philippines... |
Core Components | Engine, Gearbox, Motor, Pressure vessel, Pump |
Dimension(L*W*H) | Customized |
Description | S/F Fuel Tank |
Purpose | Diesel Storage |
Model | Underground Horizontal |
Certification | ISo9001 |
Application | Petrol Storage |
No. | Volume(m3) | Dimension (mm) |
1 | 20 | φ2200*5572 |
φ2400*4762 | ||
2 | 30 | φ2400*6976 |
φ2600*6020 | ||
3 | 40 | φ2600*7903 |
4 | 50 | φ2600*9787 |
φ2800*8518 |
Product advantages
1. Double-Layer Structure, With A Gap Of 0.1Mm To 3.5Mm Inside, And The Outer Layer Of FRP Ensures That The Leakage Will Not Directly Leak And Pollute The Soil And Water;
2. The Outer Layer Of FRP Will Not Produce Electrolytic Corrosion With Groundwater, Salt Water, Etc.;
3. The Outer Layer Of FRP Will Not Corrode With Gasoline, Diesel And Leaded Gasoline;
4. The Leak Detector Is Easy To Install, Just Insert The Probe Into The Detection Tube, And The External Monitoring Equipment And Power Supply Can Monitor The Whole Process 24 Hours A Day, Eliminating Hidden Dangers Of Pollution;
5. The Leakage Detection System Is Convenient For Detection And Maintenance, And Protects The Ecological Environment Of Soil And Water;
6. Effective Protection Of The Environment, Eliminating The High Cost Of Environmental Protection And Economic Costs In The Later Period.
-Economical And Practical
1. The Service Life Of S/F Double-Layer Oil Tanks Is 5-10 Times That Of Ordinary Oil Tanks, At Least 30 Years Of Safe Use Can Be Guaranteed; The Installation Is Convenient, The Construction Period Is Greatly Shortened, And The Cost Investment Is Reduced;
2. The Remote Monitoring System Is Convenient For Daily And Regular Inspection, Digital Control, Eliminating Manual Complicated Operations;
3. The Protection Requirement Of S/F Double-Layer Oil Tank Is 1/10 Of That Of Ordinary Oil Tank, Which Greatly Saves The Maintenance Input Cost;
4. Compared With Ordinary Oil Tanks, The Utilization Rate Of S/F Double-Layer Oil Tanks Has Been Greatly Improved, Which Ensures High-Efficiency Use Of Equipment And High Cost-Effective Products;
5. S/F Double-Layer Oil Tanks Are Highly Economical And Environmentally Friendly, And Can Effectively Protect Energy, Avoiding Serious Damage And Losses Caused By Energy Leakage.
Q1: Why Choose Gains Trade?
A1: 15+ Years Experience In FRP Industries, Have Rich Experience That Provides Different FRP Products To Fluor, Technip, Dossan, Arkema, Veolia, Wison, Dupont, Etc.
Q2: Can You Choose The Correct Raw Material For Our FRP Product?
A2: Absolutely, Pls Provide Medium & Concentration, Temperature, Pressure, Etc Technical Parameters, PP/FRP, PVC/FRP, PVDF/FRP, Etc Pipe/Tank/Tower Also Are In Our Supply Scope.
Q3: What's Your Delivery Time?
A3: We Have Several Manufacturing Plants, And Each Plant Has A Design Department And Production Facilities, We Can Finish Your FRP Products In The Shortest Time.
Q4: Which Port Is Nearest To Your Plant?
A4:From From Our Plant To Tianjin Seaport Is 300 km, To Shijiazhuang/Jinan Airport Is 150 km, And To Hengshui, High-Speed Train Station Is 30 km.
Q5:How Can We Guarantee The Quality?
A5:Always A Pre-Production Sample Before Mass Production;
Always Final Inspection Before Shipment;
Q6:Are You A Manufacturer Or A Trading Company?
A6:We Are A Manufacturer, Providing OEM & ODM Services.