KT48-1412
Waterproof Ultrasonic Sensor
Ultrasonic
Aluminum Alloy
High
Angle Probe
Gas
Ultrasonic Distance Sensor
IP67
CE/FCC/RoHS
Customized
48plus or Minus1kHz
1.36ms
1800plus or Minus15%
Greater Than or Equal To110
150
0.25~1.0m
Greater Than or Equal to-75dB
2.2g
Aluminum Alloy 6061, Hardness 90plus or Minus5hv
Default Aluminum Alloy Color (Customizable)
Pin
-40celsius~+85celsius
-40celsius~+85celsius
X:60plus or Minus15 Y:110plus or Minus15
Customization
Customization
Customization
China
9018129900
Product Description
1.Electrical performance specifications and physical characteristics | ||||||
Serial number | Description | Standard or testing result | Item | Description | Standard or testing result | |
1 | Part Number | KT48-1412 | 8 | Weight (g) | 2.2 | |
2 | Center frequency(KHz) | 48±1KHz | 9 | Sensor material | Aluminum 6061, Hardness 90±5HV | |
3 | Residual oscillation(ms) | 1.36ms | 10 | Sensor colour | Natural aluminum or customization | |
4 | Capacitance(pF)(25ºC) | 1800±15% | 11 | Operation Temperature | -40ºC~+85ºC | |
5 | RX SPL(dB) | ≥110 | 12 | Stock temperature | -40ºC~+85ºC | |
6 | Sensitivity (distance) | 0.25~1.0m≤(standard testing by Φ75mm PVC pipe) | 13 | Beam angle | X:60±15 Y:110±15 | |
7 | Recycle sensitivity | ≥-75db | 14 | Max. Input Voltage(Vp -p) | 150 | |
2,Dimension and detective diagram |
3. Environmental test | ||||||
No. | Test items | Test condition | Standard | |||
1 | High temp storage test | 144 hours at + 85 ºC | After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value | |||
2 | Low temp storage test | 144 hours at - 40 ºC | ||||
3 | High temp and high humidity storage test | 144 hours at + 65 ºC and 85 ± 5% RH | ||||
4 | Thermal shock test | Parallel 3.9k Ω resistor at both ends of the probe, keep the temp at - 40 ± 5 ºC for 0.5h, and increase the temp to 85 ± 5 ºC within 5 minutes and keep for 0.5h.100 cycles. | After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value | |||
5 | Vibration test | Products bear the vibration with frequency 10-55hz, amplitude 1.5mm,and sweep rate 1oct / min, from X, Y and Z directions for each 2 hours respectively | After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value | |||
6 | Monomer drop test | 15 free fall tests carried out from 100 ± 10cm height to 50mm thick wooden floor | After the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value | |||
7 | Strength test of outlet | Apply 9.8N pulling force between shell and wire for 30 seconds | The wire is not loose or falling off, the product function is normal, and the wire is not damaged | |||
8 | Protection level | Place the probe in 15cm deep water and soak for 24 hours | Take out the capasual from the water and install it on the test board to measure the distance. The probe works normally without long sound. | |||
9 | High and low temp characteristic test | Keep the temp at -40ºC for 2h,increase to 25ºC and keep for 2h,increase to 85ºC and keep for 2h. | After the test and place in + 25 ºC (room temp) for 2 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value | |||
10 | High and low temp working test | Under high temp 85 ºC, low temp - 40 ºC, working voltage 140 Vp-p, pulse number 20, continuous working 48 hours | Probe works normally (sensitivity and residual vibration are within normal range) |