Veinasa-HTC505
Temperature Sensor
Soil Temperature and Humidity Sensor and Controlle
0~100%(M3/M3)Rh
AC 110~220V
±5%Rh
±0.5ºC
4~20mA
-40ºC~80ºC
6cm
Stainless Steel (Electrolytic Resistance)
Veinasa
Covered with Carton Packing.
China
Product Description
Veinasa-HTC505 Digital Soil Moisture Temperature Sensor Temperature And Humidity Controller 4-20mASoil temperature and humidity controller HTC505 also known as soil temperature and humidity control instrument, mainly composed of two parts: controller instrument, soil temperature and humidity sensor.
Advantage:
1. high reliability and stability
2.meet various application needs of users
3. simple operation, high precision, low cost
1. Instrument performance index
Power supply | AC 110~220V | |
Signal input | Humidity | 0~3V, 0~5V, 1~3V, 1~5V, 4~20mA |
Temperature | 0~3V, 0~5V, 1~3V, 1~5V, 4~20mA, NTC, 18B20 (Note: part of the input signal needs hardware settings) | |
Accurancy | ±0.5% F.S ±2.0ºC | |
Alarm output contact capacity | Contact switch output, contact capacity 220VAC/5A | |
Distribution output | Twin channel: +5VDC,+24VDC (Total outpur current <150mA) | |
Working environment | Environment temperature | 0~140ºC |
Relative humidity | ≤95%RH, Avoid corrosive gas | |
Weight | ≤1000g | |
Size | 110mm*96mm*96mm |
2. Performance index of soil temperature and humidity sensor
1. Instrument performance index | ||
Power supply | AC 110~220V | |
Signal input | Humidity | 0~3V, 0~5V, 1~3V, 1~5V, 4~20mA |
Temperature | 0~3V, 0~5V, 1~3V, 1~5V, 4~20mA, NTC, 18B20 (Note: part of the input signal needs hardware settings) | |
Accurancy | ±0.5% F.S ±2.0ºC | |
Alarm output contact capacity | Contact switch output, contact capacity 220VAC/5A | |
Distribution output | Twin channel: +5VDC,+24VDC (Total outpur current <150mA) | |
Working environment | Environment temperature | 0~140ºC |
Relative humidity | ≤95%RH, Avoid corrosive gas | |
Weight | ≤1000g | |
Size | 110mm*96mm*96mm | |
2. Performance index of soil temperature and humidity sensor | ||
Humidity range | 0~100%(m3/m3)RH | |
Signal output | 4~20mA(Current tye) | |
Accurancy of humidity | ±5%RH | |
Parameter type | Soil volumetric moisture content | |
Measuring theory | Frequency domain(FDR) | |
Temperature range | -40ºC~80ºC | |
Accurancy of temperature | ±0.5ºC | |
Voltage | 12~24V (Current mode, typical 12V) | |
Working temperature range | -45ºC~80ºC | |
Measuring area | 95% of the effect is inside a cylinder centered on the central probe with a diameter of 7 cm and a height of 7cm | |
Humidity range | 0~100%(m3/m3)RH | |
Signal output | 4~20mA(Current tye) | |
Accurancy of humidity | ±5%RH | |
Parameter type | Soil volumetric moisture content | |
Measuring theory | Frequency domain(FDR) | |
Temperature range | -40ºC~80ºC | |
Accurancy of temperature | ±0.5ºC | |
Voltage | 12~24V (Current mode, typical 12V) | |
Working temperature range | -45ºC~80ºC | |
Measuring area | 95% of the effect is inside a cylinder centered on the central probe with a diameter of 7 cm and a height of 7cm |