B9D/H9D
dual Shear Beam
Resistance Strain
6-Wire
Analog Type
High Precision
Strain Gauge
Stainless Steel
IP67
OIML
Customized
1/2/5/10/30/70 Klb, 0.5/1/2.5/5/15/35t
Size and Accuracy Could Be Customed
Weighing Scales, Hopper Scales
BRANS / ZEMIC
Carton Box
high accuracy with mini size
China
84239000
Product Description
1. Name: High accuracy stainless steel shear Beam Load Cells for weighing scales
2. Material: stainless steel or Alloy steel
3. Capacity: 0.5-35t, 1-70 klb
4. Accuracy: C3/C4/C5
This bellow beam load cells has high accuracy which could replace HLC load cells directly. They also has IP68 protection class. Please contact with Brans directly if you like it.
bransensor.en.made-in-china.com
2. Material: stainless steel or Alloy steel
3. Capacity: 0.5-35t, 1-70 klb
4. Accuracy: C3/C4/C5
- Nickel plated alloy steel IP67 dual shear beam load cell
- High accuracy
- Suitable for truck and track scales and other heavy weighing devices
- Sealed construction
Specification | |||||
Maximum capacity ( Emax ) | klb | 1/1.5/2/2.5/4/5/10/15/20/25/35/50/75 | |||
Accuracy class | C3 | C4 | A5M | B10M | |
Approvals | OIML R60 C4 | III 5000 Multiple | IIIL 10000 Multiple | ||
Maximum number of load cell intervals ( nLC ) | 3000 | 4000 | 5000 | 10000 | |
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | 14000 | 15000 | 10000 | |
Combined error | %FS | ±0.020 | ±0.018 | ±0.026 | ±0.050 |
Creep | %FS/30min | ±0.016 | ±0.012 | ±0.017 | ±0.040 |
Temperature effect on sensitivity | %FS/10ºC | ±0.011 | ±0.009 | ±0.013 | ±0.040 |
Temperature effect on zero | %FS/10ºC | ±0.015 | ±0.010 | ±0.014 | ±0.020 |
Output sensitivity ( = FS ) | mV/V | 3.0±0.008 | |||
Input resistance | Ω | 700±7 | |||
Output resistance | Ω | 703±4 | |||
Insulation resistance | MΩ | ≥ 5000(50VDC) | |||
Zero balance | %FS | ±1.0 | |||
Temperature,compensated | ºC | -10 ~ +40 | |||
Temperature,operating | ºC | -35 ~ +70 | |||
Excitation, recommended voltage | V | 5 ~ 12(DC) | |||
Excitation maximum | V | 18(DC) | |||
Safe overload | %FS | 150 | |||
Ultimate overload | %FS | 300 | |||
ATEX classification (optional) | II1G Ex ia II1C T4 | II1D Ex iaD20 T73ºC | II3G Ex nL II C T4 | ||
Note: accuracy for B9D is C3, no OIML or NTEP approvals available. |
This bellow beam load cells has high accuracy which could replace HLC load cells directly. They also has IP68 protection class. Please contact with Brans directly if you like it.
bransensor.en.made-in-china.com