IT-L5
Spray Booth
CE
Steel
Powder Coating
Downdraft
Electric
Dry-type
New
600mm
<78 dB
20m2
650kg/Wheel
50mm Thick Rock Wool Panels
>1,000lux
0.38m/S
Electric Heating Tube
80 Celsius
380V, 50Hz, 3pH
68kw
INFITECH
Cargo Loaded on Steel Frame Handled by Forklifts
5000 X 4000 X 2650mm (L X W X H)
Guangzhou, China
8419899090
Product Description
Electric heating spraying and drying booth for Nippon training center
1.HIGHLIGHTSINFITECH paint and dry cabin IT-L5 comes with full glass electric sliding door. It is designed for training purpose. The full glass frontal offers full view observation of spraying operation inside the cabin.
2.SPECIFICATIONS
ITEMS | SPECIFICATIONS |
Model | IT-L5 Paint and Dry Cabin |
Internal dimensions | 5000 X 4000 X 2650mm (L X W X H) |
External dimensions | 6870 X 4110 X 3310mm (L X W X H) |
Airflow | Downdraught |
Plenum (height) | 600mm |
Basement | Pit with full grids, 800mm (high) |
Floor filtration areas | 20m2 |
Grids carrying capacity | 650kg/wheel |
Entrance door | Full glass electric sliding door, 1 set |
Service door | 800x2000mm(WxH), 1 set |
Walls | 50mm thick rock wool panels |
Upper lights (LED) | 4 sets, each 6 X 18W, 432W total |
Nether lights (LED) | 9 sets, each 2 X 8W, 144W total |
Illumination | >1,000LUX |
Filters | Pre-filter bag filter, high efficiency ceiling filter, floor filter, exhaust filter |
Intake/Exhaust unit | Direct-drive big impeller, SIEMENS motor 2x7.5KW intake fan, 28,000m3/h |
Empty loaded air speed | 0.38m/s |
Heats | Electric heating tube |
Heats - OPTION | Diesel or gas heating with heat exchanger |
Maximum working temperature | 80ºC |
Controls | PLC touch screen control |
Voltage | 380V, 50Hz, 3ph |
Rated power | 68KW |
3.FAQ
Q: Is the entrance door with full view glass insulated?
A: Yes.
Q: Can the paint and dry cabin be custom made to my design?
A: Yes, no problem to follow your requirements. We need to further check and confirm after we go through your design.
Q: Is direct gas fired heating system available with your paint and dry cabin?
A: Yes. We can offer direct fired burner. Contact us for more details.
Q: I need inverter control for the paint and dry cabin.
A: That's okay. We recommend inverter control as it can help save more than 30% energy consumption.
Q: Does the paint and dry cabin come with over-heat alarm system?
A: Yes. There is over temperature alarm. The alarm temperature is usually set at 100ºC. When the temperature is over the alarm value, the heating system will be cut off. Only when the failure is troubleshot, can the heating system be turned on.
Q: What certificate do you have for paint and dry cabin?
A: CE certificate.