Share Categories Channel

1/5
Stanford Uci224c Winding 311 30kw 37.5kVA AC Alternator for Diesel Generator Set Low Voltage 4 Pole Dynamo Original China Factory Price image 1Stanford Uci224c Winding 311 30kw 37.5kVA AC Alternator for Diesel Generator Set Low Voltage 4 Pole Dynamo Original China Factory Price image 2

Stanford Uci224c Winding 311 30kw 37.5kVA AC Alternator for Diesel Generator Set Low Voltage 4 Pole Dynamo Original China Factory Price

Fuan Tongbo Electrical Machinery Co., Ltd.

Price $20000.00 / Piece
Mini Order
-+Subtotal: $200000
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

TBS164A TO TBS404G
Industrial
Constant Speed
Three-Phase
Squirrel-Cage
Closed Type
Variable Frequency Starting
ISO9001, CCC
IP21
H
Car Type, Trailer Type, Marine, Land Use
Emergency Crew, Standby Unit, Common Units
AC Three Phase
Water Cooling Basic Diesel Generator
Fixed
Automation Type
AC Rotating Exciter
tongbo
Carton/Wooden Case/Wooden Crate
500*340*500CM
Fujian, China
85016100
Product Description

StaNford Uci224c Winding 311 30kw 37.5kVA AC Alternator for Diesel Generator Set Low Voltage 4 Pole Dynamo Original China Factory Price


Product Description

Electric Character:

EXCITATION SYSTEM:
AVR: SX440, SX460, MX321, MX341
The main stator supplies power to the exciter stator via the AVR. The exciter rotor output is provided to the main rotor by a three-phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges ecused by short circuit or lost Synchronization.  Voltage regulation of SX440 AVR with three phase induction detecting module< ±0.5 %.MX321 and MX341 suitable for the generator with permanent magnetic generator (PMG).

Electric Features

Insulation And Varnish:
The insulation system is class H.
All wound components are impregnated with materials and processes designed specifically ensure the generator running in dreadful conditions. The special developed resin materials meet rotating components.

Windings and Electrical Performance:
All generator stators are wound to 2/3 pitch, This eliminates triple(3rd,9th,15th…)harmonics on the voltage waveform and is an optimum designed for UPS equipment of non linear loads. The 2/3 pitch design avoids excessive neutral currents result from higher winding pitches. A fully consecutive damper winding reduces oscillations during paralleling. The 2/3 pitch windings and carefully pole and tooth ensures very low waveform distortion.

Terminals And Terminal Box:
Standard generators are 3-phase,and you can reconnect 12 ends of the terminals, which are mounted on a terminal block at the non-drive end of the generator. A sheet steel terminal box within AVR is provided with enough place for the customers'wiring. It has removable panels for easy access.

Telephone Influence Factor:
THF(BS EN60034-1)<2%
THF(NEMA MG1-22)<50

Mechanic Features:

SHAFT AND KEY
All generator rotors are dynamically balanced to better than minimum vibration of BS6861: part1 grade 2.5 double bearings generators are banlanced with a half key.

ENGINE ADAPTOR AND COUPLING

All generators are designed two kinds of construction. The adaptor and the drive plate is consonant with SAE standard.

LEVELS Of PROTECTION

All generators are IP2 and IP23 and IP44 can be optional for aircool protected generator. but rated power will decrease 5~10%.
The Definition Of The Product Model:

Option And Accessory
Windings temp protect thermistor and relay 
PMG
MX321 or MX341
Transformer for droop during paralleling
Product Parameters

Technical date

ModelRated Output(KW)Rated Capacity(KVA) Rated Vottage(V)Rated Current(A)Power Factor(CosфRated Speed(r.p.m)Rated Frequency(Hz)Gro$$ Weight(Kg)
TBS164A6.58.140012.30.81500/180050/6095
TBS164B8.81140015.80.81500/180050/60102
TBS164C10.813.540019.50.81500/180050/60110
TBS164012.816400230.81500/180050/60116
TBS184E1822.540032.50.81500/180050/60141
TBS184F2227.540039.70.81500/180050/60164
TBS184G2S31.340045.10.81500/180050/60180
TBS184H3037.540054.10.81500/180050/60230
TBS184J324040057.70.81500/180050/60240
TBS224C3442.540061.40.81500/180050/60225
TBS224D405040072.20.81500/180050/60270
TBS224E486040086.60.81500/180050/60290
TBS224F58725400104.60.81500/180050/60330
TBS224G6885400122.70.81500/180050/60370
TBS274C80100400144.30.81500/180050/60435
TBS274D91114400173.20.81500/180050/60460
TB5274E1121404002020.81500/180050/60510
TBS274F128160400225.50.81500/180050/60550
TBS274G140175400259.80.81500/180050/60550
TBS274H160200400288.70.81500/180050/60650
TBS314C200250400360.80.81500/180050/60910
TBS314D2362954004330.81500/180050/60975
TBS314E2603254004690.81500/180050/601055
TBS314F304380400548.50.81500/180050/601183
TBS354C360450400656.80.81500/180050/601350
TBS354D400500400721.70.81500/180050/601450
TBS3S4E480600400880.50.81500/180050/601598
TBS3S4F536670400967.10.81500/180050/601753

REMARK

All the rated are on basis of environment temperature 40#C, altitude not exceeding 1000m.

Different temperature offers different standby power, the define of standby power is  related to the standard of ISO8528-3.

All the rotors are 4 poles, as to other pole generator, please contact the manufacturer.

Generators in other voltage range depend on costumers request
 

FAQ

 

1. Delivery Time?
Spare parts about 3-5 days.
Diesel generator set about 30-50 days.

2. Manufacturer or Trade Company?
We have our own factory for OEM manufacture producing, also trade with all electrical parts.

3. Global Warranty?
Yes, usually global warranty 1 year / 1000 hours.
Provide extended warranty service for 2 years / 2000 hours, 3 years, 5 year ... ...

4. Payment terms?
L/C,  T/T,  Western Union,  PayPal

5. Customized service?
Provide customized services according to the customer requirements

Send Message

Content*

Your Name

Tel*

Email*

Shop Cart