ANEVT series dual-channel bidirectional DC power supply adopts high-frequency PWM rectification and bidirectional DCDC conversion, FPGA digital control, seamless switching between forward and reverse, automatic bidirectional operation, energy feedback to the grid at full power; advanced digital control, ultra-high control accuracy, fast response; two channels independently configured and not affect each other, which can be used in parallel to expand the DC output capacity and reduce investment by customer; abundant programming and testing functions, suitable for a variety of applications with different upper computer software.
| Voltage level | Product model | Rated current per channel (A) | Peak current per channel (A) | Rated power of the whole machine (kW)[J1] | Peak power per channel (kW) | Peak time (S) |
| 24-800V | ANEVT800-400DB | 400 | 475 | 300 | 178 | 60 |
| General parameters of dual channel ANEVT(F) series | ||
| Input parameters | Input Power | 4-phase 3-wire +PE, line voltage 380V±57V, 50/60Hz±5Hz |
| Isolation function | Built-in isolation transformer | |
| Input power factor | 0.99 (rated conditions) | |
| Input current distortion | 5% (rated conditions) | |
| Output parameters | Voltage accuracy | 0.05% F.S, resolution: 0.1V |
| Current accuracy | 0.1% F.S, resolution: 0.1A | |
| Power accuracy | 1% F.S, resolution: 10W | |
| Power supply effect | Source effect: 0.1% F.S, load effect: 0.1% F.S | |
| Ripple (Vpp) | 0.2%F.S | |
| Transient recovery time | 5 ms | |
| Current rise time | 10ms (10%~90%, resistive load, test condition: power output, load test on) | |
| Protection | IGBT overheat, IGBT overcurrent, transformer overheat, input overvoltage, input undervoltage, output overvoltage, output overcurrent, lack phase protection | |
| Three-phase line voltage | 323~437V (allowed grid voltage) | |
| Feedback parameters | Frequency | 45~65 (allowed grid frequency) |
| Power factor | 0.99 (rated conditions) | |
| Total harmonic content | 5% (rated conditions) | |
| Switching time | 10ms (forward maximum current to reverse maximum current) | |
| Feedback function | Energy feedback at full power | |
| Function | Wave editing | Control of voltage/current slope, ladder, cycle control, jump control |
| E-stop | E-stop button | |
| Battery simulation | With battery simulation function | |
| Soft start | Pre-charge | |
| Communication port | Standard Can port/RS232 port, optional RS485/LAN. | |
| Output contactor | Available and controllable | |
| Discharge protection | Discharge Unit protection unit | |
| Fan speed control | Fan temperature control and speed regulation | |
| Switch input interface | 3 channel | |
| Switch output interface | One for each channel, indicating alarm status of the channel | |
| Working environment | Temp./humidity | 0~40ºC, 10~90%RH (no condensation) |
| Altitude | ≤2000m | |