Share Categories Channel
1/6
Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 1Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 2Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 3Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 4Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 5Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor image 6

Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical, Membrapor, Gas Sensor

Advanced Sensors Application Technology Co., Ltd.

Price $200.00 / Pieces
Mini Order
-+Subtotal: $600
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
Cl2/MF(C)(S)-****
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Digital Type
Production Process
Integration
Material
Plastic
IP Rating
IP20
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
20-41mm
Origin
China
HS Code
8542330000
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
 
Gas Module Feature
- Long lifetime imported advanced electrochemical sensors
- High accuracy op ams, power supply IC, stable and sensitive
- Detect low or high concentration toxic gases precisely
- High anti-interference ability
- Over range protection, reversed polarity protection and lightning protection
- Low power consumption with a standard 4-20mA two/three-wire signal output
- Interface: pump, diffusing, flange, flange thread types
- 12-36VDC operating voltage

Detecting Range Selection
Detecting range (ppm)/SizeMiniatureCompactSlimStandard
0-20Cl2/M-20Cl2/C-20Cl2/S-20-SCl2/S-20
0-50  Cl2/S-50-SCl2/S-50
0-200Cl2/M-200Cl2/C-200Cl2/S-200-SCl2/S-200
0-2000 Cl2/C-2000  
0-5000 Cl2/C-5000  

Sensor Performance Characteristics(take Cl2/C-20 as an example)
Nominal Range0 - 20 ppm
Maximum Overload200 ppm
Expected Operation Life2 years in air
Output Signal
- 900 ±250 nA/ppm
Resolution0.1 ppm
Temperature Range- 40 °C to 50 °C
Pressure RangeAtmospheric±10%
Pressure CoefficientNo data
T90 Response Time< 60 sec
Relative Humidity Range15 % to 90 % R.H. non-condensing
Typical Baseline Range (pure air, 20°C)
< 0.1 ppm
Maximum Zero Shift (+20°C to +40°C)
- 0.2 ppm
Long Term Output Drift< 2% signal loss/month
Recommended Load Resistor10-33 Ohm
Bias VoltageNot allowed
Repeatability< 2 % of signal
Output LinearityLinear

Sensor Physical Characteristics
Weight~ 13 g
Position SensitivityNone
Storage LifeSix months in container
Recommended Storage Temperature5 °C - 20 °C
Warranty Period12 months from date of dispatch

Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control


 