Share Categories Channel
1/5
Disinfection Cabinet O3 Ozone Sensor Module 0-10ppm 0-100ppm, Disinfection Cabinet Ozone Sensor, Disinfection Cabinet Sensor image 1

Disinfection Cabinet O3 Ozone Sensor Module 0-10ppm 0-100ppm, Disinfection Cabinet Ozone Sensor, Disinfection Cabinet Sensor

Xi'an Gavin Electronic Technology Co., Ltd.

Price $19.00 / Pieces
Mini Order
-+Subtotal: $190
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
GALOCE
Type
Electrochemical Gas Sensor
Production Process
SemiConductor Integrated
Range
0-10ppm/0-100ppm
Trademark
GALOCE
Transport Package
Export Package
Origin
China

Disinfection Cabinet O3 Ozone Sensor Module 0-10ppm 0-100ppm

Description


GMQ series ozone sensor module is a general-purpose gas module that combines the electrochemical detection technology developed by our company and the sophisticated circuit design. The use of electrochemical principles to detect the concentration of ozone gas in the air has the characteristics of high sensitivity, high resolution, low power consumption and long service life. Built-in temperature sensor for temperature compensation. UART interface output can be provided to facilitate the back-end reading data.

Features:
1. High sensitivity
2. High resolution
3. Good stability
4. Long service life
5. Strong anti-interference ability
6. Temperature compensation
7. Low power consumption

Application

Disinfection cabinets

Portable instruments

Air quality monitoring equipment

Smart home equipment and other places.

 

Detail Show


 

Specification 

ModelGMQ125GMQ114
Range0-10ppm0-100ppm
Resolution 0.01ppm0.1ppm
OutputUART output (3V level)UART output (3V level)
Warm up time≤3min≤30s
Response time≤90s≤30s
Recovery time≤90s≤30s
Working voltage3.7~5.5VDC5±0.5VDC
Working temperature -10ºC~55ºC-10ºC~65ºC 
Working humidity 15%~90% RH 15%~90% RH
Storage temperature -20ºC~55ºC-20ºC~65ºC 
Service life 2 years (in the air)3-5 years (in the air)

 

 
Note:
 
1.GMQ125 can provide DAC output (0.4 ~ 2V voltage signal corresponding concentration: 0 ~ 10PPM).
2.When using the sensor module, it is necessary to avoid gas interference such as alcohol.

Product size and wiring

Send Message

Content*

Your Name

Tel*

Email*

Shop Cart