4-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit, Differential Pressure Sensor, Piezoresistive Silicon Die image 14-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit, Differential Pressure Sensor, Piezoresistive Silicon Die image 24-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit, Differential Pressure Sensor, Piezoresistive Silicon Die image 3

4-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit, Differential Pressure Sensor, Piezoresistive Silicon Die

Hangzhou RUNPAQ Technology Co., Ltd.

Price $12.20 / Pieces
Mini Order
-+Subtotal: $1220
Availability In Stock
Purchase details

Payments:

Returns&Refunds:

Eligible for returns and refunds View More

Model NO.
501I
Wiring Type
Four-Wire
Measuring Medium
Liquid
IP Rating
IP68
Certification
RoHS
Customized
Customized
Transport Package
Foam+Carton
Specification
dia. 19mm
Trademark
Runpaq
Origin
China
Type:
Piezoresistive Pressure Sensor
Component:
SemiConductor Type
For:
Diffused Silicon Pressure Transmitter
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Stainless Steel
4-20mA or 0.5-4.5Vdc Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit

Brief Introduction
Flush diaphragm ceramic pressure sensors are made with a ceramic base plate and a flush diaphragm and work following the piezoresistive principle. The Wheatstone bridge is screen printed on one side of the flush ceramic diaphragm which is, in turn, glued to the sensor's body. The bridge faces the inside where a cavity is made and the diaphragm's opposite side can therefore be exposed directly to the medium to be measured.Because of the Al2O3 ceramic excellent chemical resistance (aggressive gases, most of solvents and acids, etc.),
no additional protection is normally required.
Ceramic pressure sensors are thermally compensated by laser-adjustable PTC resistors and the use of ceramic ensures a high linearity across the entire range of measurement, reducing effects of hysteresis to a minimum.

501I pressure sensors module is integrated with pcb which amplify the output from mv to analogy signal such as 0.5-4.5Vdc or 4-20mA.
Because of the Al2O3 ceramic excellent chemical resistance (aggressive gases, most of solvents and acids, etc.), no additional protection is normally required.
 
ApplicationsKey features & advantages
• Cooling equipment & A/C system
• Automotive and vehicle
• Industrial process control
• HVAC system
• Refrigeration equipment
• Air conditioning unit
• Pressure range 0bar‐50bar
• Excellent resistance to corrosion and abrasion
• Absolute measurement available
• Thermally compensated
• Extended customization
• Extended choice of measuring ranges
 
Technical parameters
ParameterUnitDescription
sensor type-flush diaphragm, absolute (A), gauge (R) or sealed gauge (S)
technology-piezoresistive
diaphragm material-ceramic Al2O3 96% (standard), 99.6% or sapphire (on request)
weightg< = 8 (ceramic cell only)
response timems<= 1
supply voltage VDCVDC2...30
offsetmv/v-0.1 ~ +/-0.1 (other nominal values available on request)
current cons.mA< = 1.3 @ 10V
operating temperature°C‐40...+135 (‐40 °F...+275 °F)
storage temperature°C‐40...+150 (‐40 °F...+302 °F)
impedance11+/- 30%
nominal pressure FSObar0.5125102050100200400600800
psi7142973145290725145029005800870011600
overload pressurebar1241015351001503505007501000
psi14295814521750714502175507572501087514500
burst pressure
 
bar2361525651202005006509501250
psi29438721736294217402900725094251377518125
vacuum capability
 
bar-0.1-0.5-1-1-1-1-1-1-1-1-1-1
psi-1.4-7-14-14-14-14-14-14-14-14-14-14
type-RA/R/SA/R/SA/R/SA/R/SA/R/SA/R/SSSSSS
total thicknessmm6.156.176.236.306.356.556.706.707.057.327.558.05
in0.2420.24320.2450.2480.2500.2580.2630.2630.2780.2880.2970.317
sensitivity 2mv/v1.4-2.42.0-3.62.3-3.52.3-4.03.1-5.52.4-4.04.0-6.03.0-4.82.5-3.93.1-4.83.1-4.82.0-3.5
accuracy 3%/fs0.4/0.90.3/0.90.3/0.60.2/0.40.2/0.50.2/0.50.2/0.50.2/0.50.4/0.90.5/1.00.5/1.00.5/1.0
thermal offset shift(typ./max)%/fs/k± 0.005 / ± 0.040 25 °C...85 °C (77 °F...185 °F)
thermal span shift%/fs/k≤ ± 0.010                          0 °C...70 °C                                                    (32 °F...158 °F)
≤ ± 0.012                          -25 °C...0 °C / 70 °C...85 °C                          (-13 °F...32 °F / 158 °F...185 °F)
≤ ± 0.014                          -40 °C...-25 °C / 85 °C...135 °C                     (-40 °F...-13 °F / 185 °F...275 °F)
reliability tests 4-1000 hours @85 °C (185 °F) & 85 %RH 500                       thermal shocks ‐40°C...+150 °C (‐40 °F... +302 °F)
1000 hours burn‐in @150 °C (302 °F)                                  10 million 0 bar to Pnom pressure cycles
Tests performed at 25°C in Metallux housings, unless otherwise specified. Different housings may affect performances.
1. Psi values for reference only.
2. The sensitivity of each production batch is constant, within the indicated range and with minimal dispersion.
3. Accuracy =√NonLinearity2+Hysteresis2 +NonRepeatability2, terminal based.
4. All technical characteristics will remain within indicated ranges performing the above-mentioned reliability tests.


Drawing & wiring diagram

Top view
4-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit
Schametics

4-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit
Model selections
4-20mA or 0.5-4.5VDC Ceramic Pressure Sensor Module, Optional PCB for Air Conditioning Unit
Note: 1. Extremely attention must be paid to sensor installation process to avoid any miss conduction that affect the sensor performance,
2. please protect the diaphragm and the compensated board carefully to prevent any damage. 3.  Please contact us if your requested working
temperature lower than -20ºC

Send Message

Content*

Your Name

Tel*

Email*