Motor capacity (KW) | Traveling height H | Traveling height H | ||
1000-3000 | 5.5 | 1000-3200 | 5.5 | |
3000-4000 | 7.5 | 3300-4200 | 7.5 | |
4100-4200 | 8 | 4300-4400 | 8 | |
4300-6800 | 11 | 4500-7000 | 11 | |
6900-9000 | 15 | 7100-9200 | 15 | |
Center supporting height H1 | When the traveling height 2600center support.And supporting height is H1=H/2-780. | |||
Center supporting height H1 Center supporting height H2 | When the traveling height 5800supports.The traveling height of first one is H1=H/3-881,and second one is H2=2H/3-681. | |||
Power supply Use needs to supply 380V AC 50Hz three-phase five-wire power supply. Voltage should ≤10 when moving walk at the start and the voltage should be ≤5 in normal operation,Maximum starting current should less than3.5 times of rated current. |
Technical notes | ||
Dip angle α | 12° | |
Speed V | 0.5m/s | |
Step width A | 1000 | 800 |
Handrail inner side distance B | 1158 | 958 |
Handrail center distance C | 1238 | 1038 |
Moving walk outside width D | 1600 | 1400 |
Supporting beam length E | 1660 | 1460 |
Exterior barrler width F | 2310 | 2110 |
Pit width G | 1660 | 1460 |
Support opposite force R1[kN] | 0.009xL11+22 | 0.0078xL11+19 |
Support opposite force R2 [kN] | 0.009xL12+10 | 0.0078xL12+9 |
Support opposite force R3 [kN] | 0.0117x[L1+L2] | 0.01014x[L1+L2] |
Support opposite force R4 [kN] | 0.0117x[L2+L3] | 0.01014x[L2+L3] |
Notes
1 .When the moving walk is installed in the second floor and above, pit is canceled. And the bottom and exit of construction should be symmetrical.
2.sufflcient unblocked space is needed at entrance and exit of moving walk. The width should not less than 1310 and the depth from handrail belt swerving edge lo any barrier should not less than 2500.
3. the distance between moving walk and any barrier should≥500
4.User needs Io Supply a earth connection equipment with resistance less than 4 ohm.
5.When the traveling height H≤2600,cancal to support R3, R4.
6.when the travelling height 2600
7.When the traveling height 5800< H≤7800, we only need 10 support R3, R4 and L1=12=13=1/3.
8.This plan Is current 12°standard moving walk construction size, if the construction can not be executed, please contact Technology Department
9.The unit in this plan millimeter. We reserve right to change without prior notice.
12° Moving walk construction layout drawing