Special devices: medical X Ray or CT imaging equipment, medical equipment cabinet, disinfection lamp, monitoring system device, power generation device and other equipment, can provide medical support, complete medical inspection and diagnosis and emergency rescue functions
Special device: X-ray machine, mainly used for mobile medical inspection
Experience on Expansion of Field Battle X-ray Diagnosis Vehicle and Field Battle Operation Vehicle ,Ambulatory,
Price for refer only. Final Price Offer Discount.
Main technical parameters
Overall dimensions: | 9760×2520×3965,3820(mm) | Fuel Type: | Diesel oil |
Gross Weight | 15300(Kg) | ||
Net weight | 15105(Kg) | Rated load | (Kg) |
Approach Angle/Departure Angle: | 16/10(°) | Front/rear overhang: | 1450/2710(mm) |
Axle Load: | 5895/9405 | Wheelbase: | 4500,4700,5000,5200,5600,5800, 6300,3600,3800,4200(mm) |
Axle Number | 2 | Maximum speed: | 110(km/h) |
Tire Number | 6(PCS) | Tire Specifications: | 295/80R22.5 18PR,12R22.5 18PR,11.00R20 18PR,10.00R20 18PR,275/80R22.5 18PR,295/60R22.5 18PR,315/60R22.5 18PR,12.00R20 18PR |
Fuel consumption: | (L/100Km) | Number of spring pieces: | 3/4,2/3+2,3/3+2,3/9+8,3/7+3,3/7+6,7/7+3,7/7+6,11/9+8,3/-,3/2+-,2/2+-,2/- |
Front wheel track: | 1900,1950,1998,2015,2035(mm) | Rear wheel track: | 1850(mm) |
Engine | Engine manufacturer | Displacement (ml) | Power (kw)/ horsepower (ps) |
MC07.29-60;MC07.31-60;MC07.33-60;MC07.25-60;WP7.270E61;WP6H245E61;MC07H.35-60;MC07H.33-60;MC07.34-60;MC07.27-60;MC05H.25-60;WP8.350E61;WP7.300E61;WP6H270E61;MC07H.29-60;WP7H270E62;WP7H300E62;WP7H320E62 | Weichai Power Co., LTD. China Heavy Duty Automobile Group Co., LTD | 6870;6870;6870;6870;7470;6220; 7360;7360;6870;6870;4910;7800; 7470;6220;7360;6800;6800;6800 | 213;228;240;188;199;180;257;240;251;202; 180;257;220;199;213;199;221;235 |
Technical requirements:
1, vehicle composition: second class chassis, aluminum alloy box
2, the operation car is divided into: equipment room, preparation room, operating room three areas; The front part is the equipment area, the middle part is the operation area, and the back part is the doctor preparation area and nursing area. Equipment room: equipped with air purification system and electrical system; The preparation room is located at the rear end, with a rear entrance, wash basin, testing table, mobile stretcher bed, 1 set of medicine refrigerator, 1 set of dressing cabinet, and 1 set of distribution cabinet. The circulation doors of the preparation room and operating room are electric doors. Operating room safety
Equipped with: comprehensive operating bed, operating shadowless lamp, wash basin, medical equipment fixing device.
3. Cleanliness of the central area of the operating room: ≥ 10,000, cleanliness of the preparation room: ≥ 100,000;
4. Vehicle function: The special function and device description of the parameters announced by the Ministry of Industry and Information Technology of the operating vehicle contain the words "operating bed, operating shadowless lamp, medical operation and other functions".
5, overall size (length * width * height mm) : ≥10000*2500*3600
6, maintenance quality (Kg) : 13000-25000.
7. Departure Angle/approach Angle (°) : ≥16/9.
8, front suspension/rear suspension (mm):≥1400/2700.
11. Number of axes: ≥2.
12. Number of tires :≥6.
13. Rear wheel base (mm) : ≥1820.
14, engine: straight six cylinders, water-cooled, supercharged intercooled, high pressure common rail.
15, power (kW) : ≥169.
16. Displacement (ml) : ≥6200.
17, the operation vehicle is a fixed shelter type, no water, suitable for field high temperature, cold, high altitude area; The compartment should be large plate, large plate square cabin assembly, extensible, double-side electric drive, but also in the case of no power supply can be manually completed cabin shrinkage.
18, compartment floor material requirements:
Odor requirements: wet (23ºC) odor grade ≤2.0 (provide test report)
Odor requirements: wet (40ºC) odor grade ≤2.5 (provide test report)
Odor requirements: Odor level ≤3.0 under dry state (80ºC) (provide test report)
Combustion characteristics requirements: The maximum combustion speed in an environment with 50% relative humidity (23 ° C) ≤A-0mm/min.
19, the car body is made of high-strength corrosion-resistant aluminum plate and square tube skeleton, welding and bonding process.
20, heat insulation requirements: body with heat insulation layer.
21, environmental requirements: medical cabin interior decoration materials need to be environmentally friendly materials.
22, doors and Windows: sealed.
23, door: back door to open 1, equipment cabin maintenance door 2.
24. 1 set of ladders: used for operation and maintenance between equipment.
25, hydraulic support system: four support legs share a set of hydraulic cylinders.
26, hydraulic lifting tailboard system (for rescued personnel on and off the vehicle) : the vehicle tailboard is set up with a set of hydraulic tailboard, the load is required to be ≥2 tons, can be landed, the material is steel. Set up ramp pedals and cart into the cabin. It must be firmly connected with the body structure or connecting parts, and has sealing.
27, tail plate surface size (length X width /mm) : ≥2200*1850.
28, the maximum lifting height (mm) : ≥1500.
29, the maximum load (kg) : ≥2000.
30, skirt box: The lower part of the car is installed with skirt cabin, skirt cabin is composed of skeleton and cabin door combination, skirt cabin skeleton is connected to the side wall of the cabin, and the whole cabin forms a whole, the skeleton is installed with cabin door, the cabin door is installed with gas spring, door lock, hinge, etc., the cabin door is an upturned door, the skirt door uses aluminum alloy hinge, the door and cabin are carbon steel material.
Air purification system
1, configure a set of air conditioning purification integrated system, installed in the equipment room. It is required that the doctor's preoperative preparation area and the patient's preoperative preparation area be purified in millions of levels. The operation area is purified at 100,000 level, including: air conditioning, purification unit, ventilation pipe, return air pipe, laminar ceiling at the end, high efficiency filter at the end, air volume control valve, pipe silencer, pipe insulation and fixing, temperature control system, etc.
2, cleanliness: 100,000-10,000.
3, room temperature: 18-26ºC.
4. Number of air changes (times /h) : ≥50.
5, operating room and outdoor pressure difference (Pa) : ≥20.
6, illumination (LM) : 200-300.
7, purification unit: The box adopts special insulation materials for the box, the box is equipped with a supply fan and a junior high efficiency filter, the air supply port is set up on the side of the purification unit box, and the top surface is installed with a return air port and a supply air port, the air supply fan will breathe the indoor air through the return air port to the purification unit box, and then through the primary, middle and high efficiency filter from the air supply port to the room, the reciprocating cycle to purify the operating room air.
8, the unit internal filtration: the initial effect filter: filter 0.5um particles; Efficiency: 40-50%; Bag type medium effect filter: filter 0.5um particles; Efficiency: 70-80%.
9. The end laminar flow ceiling is installed on the top of the operating room operating bed, and 6 high-efficiency filters are installed inside the laminar flow ceiling to filter 0.5um particles; Efficiency: ≥99.99%, the air from the air supply outlet of the purification unit passes through the air supply pipe and the air volume regulating valve to the high efficiency filter at the top of the operating room.
Each working area forms an internal circulation system. The operation area is equipped with fresh air, circulating air and exhaust air systems, and the return air of the air conditioner is connected to two working areas.
10. A high efficiency filter is installed at the top of the preparation chamber. The air coming out of the air supply outlet of the purification unit goes through the air supply pipeline and the air volume regulating valve to reach the high efficiency filter at the top of the high efficiency preparation chamber.
11. The air conditioner and the purification unit box are connected in series. The air conditioner is connected in series between the return air pipeline and the purification unit box. The air coming out of the air conditioner is filtered through the filter inside the purification unit and then served indoors to ensure the cleanliness of the indoor air.
Fresh air volume: ≥500m³;
Return air volume: ≥3000m³;
External residual pressure :≥800Pa;
Motor: low noise centrifuge;
Fan: frequency conversion, high static pressure;
Compressor: frequency conversion, single cooling type (8 pieces);
Indoor cooling capacity :≥19KW;
Electric auxiliary heat: ≥15KW;
Comprehensive maximum operating power: ≥22KW;
Comprehensive maximum starting current: frequency conversion starting;
Unit noise: ≤70dB;
Air supply mode: backward and upward;
Temperature control range: 22ºC~26ºC;
Moisture control range: 50%~60%;
Heat exchanger type: copper tube with aluminum fin;
Rated power: ≥22KW;
Control system: computer board, language customization (Chinese), touch screen; Throttle mode: electronic expansion valve.
12, the air volume control valve regulates the positive pressure difference between the operating room, the preparation room and the outside, and the pressure difference between the operating room and the preparation room. The purification unit is installed with a return air outlet and a supply air outlet, and the supply fan draws the indoor air through the return air outlet to the purification unit box, and then passes through the primary, middle and high efficiency filters from the air outlet to the room, and the reciprocating cycle purifies the air in the operating room.
Oxygen supply system
1. The vehicle is equipped with a set of oxygen supply system, which is composed of 2 groups of oxygen cylinders and 1 set of air extractor. Store two oxygen cylinders (capacity ≥40L)
The body is connected with structural parts or connectors, and has tightness. The oxygen terminal is installed in the surgical area, equipped with oxygen and air interfaces. The terminal is quick drawing Structure;
2. The oxygen cylinder is discharged in parallel to the pressure reducing valve and enters the oxygen inhalation terminal in the operating room.
3, with pressure relief device, oxygen pressure gauge, valve, oxygen alarm device safety measures.
4, oxygen terminal equipped with oxygen quick plug socket, humidification bottle.
5. Oxygen alarm device is installed inside the operating room to alarm when there is overpressure or underpressure in the oxygen pipeline. Carbon dioxide storage cabinet, store 1 bottle of Carbon dioxide, need to be connected with the body structure or connector, and have sealing, cylinder capacity ≥15L.
6, air compressor: power: ≥680W; Exhaust volume ≥128L/min.
Water supply and drainage system
1, water tank: 1 set of ≥200L sewage tank, 1 set of ≥200L clean water tank, there is a corresponding waterway system, equipped with electronic level meter, water tank material must be 304 stainless steel, need to be firmly connected with the body structural parts or connectors.
2, pure water filtration device: the water entering must be purified by multiple stages before it can be entered, that is, it requires the transformation of the filter screen at the water inlet, the installation of the water purification device, and the modification of the waterway system pipeline. The original water tank is purified by the water purification system and then input into the clean water tank
3, water purification system parameters:
(1) Ro central water treatment purifier;
(2) Purification level: up to 5 filter element filtration;
(3) Water quality: pure water;
(4) Water yield: ≤80L/h;
(5) Filtration accuracy: 0.01-0.0001 micron;
(6) Use water pressure: 0.1-0.3Mpa.
3, hand sterilizer: 1; The hand sterilizer should be a transparent bottle with a volume ≥350ml.
4. Sink system: installed in the doctor's preoperative preparation area, it must be a special high faucet for the operating vehicle, equipped with an induction water outlet device, a physical and chemical board table, an embedded 304 stainless steel pool, and a corresponding waterway system. The size of the pool shall be ≥800mm* 550mm, and the faucet shall also be equipped with an outlet heat device.
5, dryer: 1. The hand dryer is hot and cold, rated power ≥1200W,
Super quiet generator:
1, power ≥40KW, need to be firmly connected with the body structural parts or connectors.
2, water cooled engine, water cooled muffler.
3. It can start normally and output rated power under low pressure (height) of 3000 meters
4, noise: ≤70 decibels (test within one meter)
Operating shadowless lamp:
1, illuminance (adjustable) : 4000-180000lux;
2, color temperature (adjustable) : 3700K-5000K;
3, color rendering index: 85-98;
4, light column depth: ≥1300mm;
5, spot diameter: 200-260mm;
6, illumination adjustment: 1%-100%;
7, lamp type: LED;
8. Number of bulbs: ≥80;
9, lamp power: ≥1W×80;
10, bulb average life: ≥80000h;
11, the surgeon head temperature rise: <1ºC;
12, power supply voltage: AC100-240V, 50/60HZ;
13, the use of LED cold light source, illuminance 3000-160000LUX, endless dimming non-multi-level adjustment; The color temperature is in the range of 3700K-5000K. At the same time to meet the high illuminance, according to the needs of different surgeons, adjust the illumination parameters;
14, LED light chip, chip service life ≥ 80,000 hours or more;
15, color rendering index 85-98;
16, the surgeon head temperature rise ≤1ºC;
17, the lampshade shell is made of aluminum, the surface is high voltage electrostatic spraying;
18, the middle disinfection handle can be arbitrarily disassembled, temperature ≥134ºC, high pressure ≥205.8kPa.
Electric operating table:
1. Pass EMC electromagnetic compatibility test to ensure that the weak line of internal information system is not interfered by electromagnetic signal
2, the minimum operating table can reach 700mm, the maximum can reach 1000mm, lifting stroke ≥300mm.
3. Table length ≥2010mm, width ≥500mm, the bottom of the operating bed can be accurately and quickly positioned in the knee elbow position, lateral position, lithotomy position, seat position, supine position.
4. The operating table is equipped with a built-in waist bridge, and the lifting distance of the waist bridge is ≥110mm.
5, the leg plate is a split-leg design, abduction ≥90°, lower fold ≥90°, while equipped with detachable structure, it can also be connected with orthopaedic traction frame after disassembly for lower limb traction surgery.
6. The leg plate adopts gas spring.
7. Operating table bearing capacity ≥200kg.
8, operating table lifting cover cylinder, base cover shell, guide rail and accessories are stainless steel materials.
9, the whole table can be translated forward and back, the distance is ≥400mm, to achieve all C-arm photography without blind spots.
10, operating table head plate fold ≥50°, fold ≥90°, at the same time removable. Upper fold ≥75°, lower fold ≥10°; Table tilt left and right ≥20°, forward ≥25°, back ≥20°.
11, the table should be made of medical high light transmittance material.
12, the mattress adopts memory sponge cushion, thickness ≥60mm.
13. The material of the flammable part of the operating table meets the flame retardant requirements stipulated by CAN/CGSB-155.20-2017.
14, the operating table is equipped with rechargeable batteries, a single charge can meet the needs of ≥50 operations.
15, the whole equipment adopts low-voltage DC motor drive, electric motor drive system.
16, electric control lifting, leaning left and right, leaning back and forth, the backplane folded up and down, the table longitudinal translation.
17, with foot diagonal brake system, the brake is located on the foot side, left and right activity pedal type, four-point landing.
18. Configure mute casters.Customizing Japan 4WD 4x4 OFF ROAD Diesel Medical All-terrain Ambulance (IISUZU Mobile Clinic Truck) China Hospital Medical Mobile Station Truck Mobile Health Clinic Medical Vehicle
Basic Parameters
Dimension (mm):11990*2500 (expanded 3800) *3990 | Cabin dimension (mm):9307*3645*2105 |
Maximum total mass (kg) : 18245 | Maximum speed (km/h) : 110 |
Number of passengers in the cab:3 | Maximum net power (kW) : 245 |
Fuel type: diesel | Ground clearance ≥280mm |
Chassis:SINOTRUCK SITRAK | Gearbox:9-speed automatic |
Engine:MC07.34-50 | Displacement (ml): 6870 |
Maximum net power (kW) : 245KW | Maximum torque/speed (N.m/(R /min) : 1250/1200-1800 |
Extension Compartment System
Transmission mechanism: NMRV075 PS70 -- HD14 | Reduction ratio: 60*8 |
Output speed (rpm): no load 3.75, load 3.1 | Output torque (Nm):290 |
Extension width on both sides of the extension compartment (mm):650 | Extension and recovery time of extension compartment (s): about 50 |
Electrical System
Supply power:220V alternating current or use vehicle-mounted generator | Output voltage precision:≤5% |
Equipment:voltage protection device |
Waterway system
Water tank:80L water tank, 60L sewage tank | Water pump:DP-100 micro diaphragm water pump |
Hand dryer:KV-8268A automatic high-speed hand dryer | Hand sterilizer :KV-2012S |
1.Are you trading company or manufacturer ?
We are Group Corporation manufacturer ,have Group Factories Contractor.2 .Can I have samples of this type of product to test the quality?
Yes, you can buy any sample to test the quality,our MOQ is 1 unit.
3. What's the delivery time and can you lower the price?
It depends on your order.The delivery time is within 30 workdays after we received your prepayment. If you have placed an order of large quantities, then,of course, the price can be lowered.
7.What's the payment terms?
8. How to guarantee customers get the goods smoothly after they payment?
Don't worry,dear.We have joined the trade assurance,you can place the order by trade assurance,if we don't delivery products, the deposit will be returned to you.
9.How can you ensure the quality of the products?
Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.