30Kwh Energy Storage System UPS Mobile Moveable Charge Station
No. Item Index Remarks
1 output voltage DC250V-750V continuously adjustable
2 Output current 0-60A The actual charging current will be intelligently adjusted with changes in temperature and SOC margin
3 charging interface Single gun by 2015 new national standard interface / agreement
4 charging mode by time, by the power, by the amount and automatically filled
5 charging mode automatically
6 display 7-inch true color TFT LCD touch screen protocol defined in a variety of parameters, in particular, all the monomer voltage and temperature
7 Output voltage accuracy ≤ ± 0.5%
8 regulator accuracy ≤ ± 0.5%
9 Output current accuracy ≥30A: not more than 1% The actual state of the battery charge
10 steady flow accuracy ≤ ± 1% The actual state of the battery charge
11 Ripple and noise ≤ ± 0.5% 20MHz bandwidth limit
12 current unbalance ≤ 5%
13 Output overshoot voltage ≤110% Steady state output voltage
14 Power frequency / impulse withstand voltage 2500VAC 1 minute, total leakage current <10mA, impulse voltage 12kV Each charged circuit, between live circuit (metal shell)
15 Dielectric strength 10MΩ @ 1000Vdc each charged circuit, the live circuit to ground (metal case) between
16 Charging Interface / Protocol GB Interface / Protocol By 2015 New GB interface / protocol